fix: JSON.parse of wea selector values correctly replaces " allowing mw to be parsed
Deploy Standortplaner / deploy (push) Successful in 16s
Details
Deploy Standortplaner / deploy (push) Successful in 16s
Details
This commit is contained in:
parent
3ce303a00f
commit
2c6eac1c99
23
app.js
23
app.js
|
|
@ -386,11 +386,13 @@ document.addEventListener('DOMContentLoaded', async () => {
|
||||||
const fr = overrideData?.fr || Number.parseFloat(inputFoundation?.value) || 15;
|
const fr = overrideData?.fr || Number.parseFloat(inputFoundation?.value) || 15;
|
||||||
let type = overrideData?.type || "Standard Typ";
|
let type = overrideData?.type || "Standard Typ";
|
||||||
let hersteller = overrideData?.hersteller || "Unbekannt";
|
let hersteller = overrideData?.hersteller || "Unbekannt";
|
||||||
|
let mw = overrideData?.mw || null;
|
||||||
if (!overrideData && weaTypeSelector && weaTypeSelector.value) {
|
if (!overrideData && weaTypeSelector && weaTypeSelector.value) {
|
||||||
try {
|
try {
|
||||||
const parsed = JSON.parse(weaTypeSelector.value);
|
const parsed = JSON.parse(weaTypeSelector.value.replace(/"/g, '"'));
|
||||||
type = parsed.anlagentyp;
|
type = parsed.anlagentyp;
|
||||||
hersteller = parsed.hersteller;
|
hersteller = parsed.hersteller;
|
||||||
|
mw = parsed.nennleistung;
|
||||||
} catch(e) {}
|
} catch(e) {}
|
||||||
}
|
}
|
||||||
const weaNr = overrideData?.nr || loadedNr || (state.turbines.length + 1).toString();
|
const weaNr = overrideData?.nr || loadedNr || (state.turbines.length + 1).toString();
|
||||||
|
|
@ -418,7 +420,7 @@ document.addEventListener('DOMContentLoaded', async () => {
|
||||||
id: `WEA_${Date.now()}`,
|
id: `WEA_${Date.now()}`,
|
||||||
nr: weaNr,
|
nr: weaNr,
|
||||||
variant: overrideData?.variant || state.activeVariant,
|
variant: overrideData?.variant || state.activeVariant,
|
||||||
hersteller, type, rd, hh, fr, latlng,
|
hersteller, type, mw, rd, hh, fr, latlng,
|
||||||
ksfAngle, ksfMirrored,
|
ksfAngle, ksfMirrored,
|
||||||
totalHeight: geoms.totalHeight,
|
totalHeight: geoms.totalHeight,
|
||||||
layers: {
|
layers: {
|
||||||
|
|
@ -555,11 +557,13 @@ document.addEventListener('DOMContentLoaded', async () => {
|
||||||
const newNr = editNr.value;
|
const newNr = editNr.value;
|
||||||
let newManufacturer = activeTurbine.hersteller;
|
let newManufacturer = activeTurbine.hersteller;
|
||||||
let newType = activeTurbine.type;
|
let newType = activeTurbine.type;
|
||||||
|
let newMw = activeTurbine.mw;
|
||||||
if (editWeaSelector && editWeaSelector.value) {
|
if (editWeaSelector && editWeaSelector.value) {
|
||||||
try {
|
try {
|
||||||
const parsed = JSON.parse(editWeaSelector.value);
|
const parsed = JSON.parse(editWeaSelector.value.replace(/"/g, '"'));
|
||||||
newManufacturer = parsed.hersteller;
|
newManufacturer = parsed.hersteller;
|
||||||
newType = parsed.anlagentyp;
|
newType = parsed.anlagentyp;
|
||||||
|
newMw = parsed.nennleistung;
|
||||||
} catch(e) {}
|
} catch(e) {}
|
||||||
}
|
}
|
||||||
const newRd = Number.parseFloat(editRd.value);
|
const newRd = Number.parseFloat(editRd.value);
|
||||||
|
|
@ -575,6 +579,7 @@ document.addEventListener('DOMContentLoaded', async () => {
|
||||||
activeTurbine.nr = newNr;
|
activeTurbine.nr = newNr;
|
||||||
activeTurbine.hersteller = newManufacturer;
|
activeTurbine.hersteller = newManufacturer;
|
||||||
activeTurbine.type = newType;
|
activeTurbine.type = newType;
|
||||||
|
activeTurbine.mw = newMw;
|
||||||
activeTurbine.rd = newRd;
|
activeTurbine.rd = newRd;
|
||||||
activeTurbine.hh = newNh;
|
activeTurbine.hh = newNh;
|
||||||
activeTurbine.fr = newFr;
|
activeTurbine.fr = newFr;
|
||||||
|
|
@ -2411,6 +2416,7 @@ document.addEventListener('DOMContentLoaded', async () => {
|
||||||
variant: t.variant,
|
variant: t.variant,
|
||||||
hersteller: t.hersteller,
|
hersteller: t.hersteller,
|
||||||
type: t.type,
|
type: t.type,
|
||||||
|
mw: t.mw,
|
||||||
rd: t.rd,
|
rd: t.rd,
|
||||||
hh: t.hh,
|
hh: t.hh,
|
||||||
ksfAngle: t.ksfAngle,
|
ksfAngle: t.ksfAngle,
|
||||||
|
|
@ -2480,6 +2486,7 @@ document.addEventListener('DOMContentLoaded', async () => {
|
||||||
nr: t.nr,
|
nr: t.nr,
|
||||||
hersteller: t.hersteller,
|
hersteller: t.hersteller,
|
||||||
type: t.type,
|
type: t.type,
|
||||||
|
mw: t.mw ? Number.parseFloat(t.mw) : null,
|
||||||
rd: Number.parseFloat(t.rd) || 160,
|
rd: Number.parseFloat(t.rd) || 160,
|
||||||
hh: Number.parseFloat(t.hh) || 165,
|
hh: Number.parseFloat(t.hh) || 165,
|
||||||
ksfAngle: Number.parseFloat(t.ksfangle ?? t.ksfAngle ?? 0),
|
ksfAngle: Number.parseFloat(t.ksfangle ?? t.ksfAngle ?? 0),
|
||||||
|
|
@ -2741,16 +2748,8 @@ document.addEventListener('DOMContentLoaded', async () => {
|
||||||
const latlng = t.layers.marker.getLatLng();
|
const latlng = t.layers.marker.getLatLng();
|
||||||
const utmCoords = proj4(wgs84, utm32, [latlng.lng, latlng.lat]);
|
const utmCoords = proj4(wgs84, utm32, [latlng.lng, latlng.lat]);
|
||||||
|
|
||||||
// Nennleistung aus loaded types finden
|
|
||||||
let nennleistung = '-';
|
|
||||||
if (window.availableWeaTypes) {
|
|
||||||
const matchedType = window.availableWeaTypes.find(w => w.hersteller === t.hersteller && w.anlagentyp === t.type);
|
|
||||||
if (matchedType && matchedType.nennleistung) {
|
|
||||||
nennleistung = matchedType.nennleistung;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
const anlagentyp = t.type === 'Standard Typ' ? '-' : (t.type || '-');
|
const anlagentyp = t.type === 'Standard Typ' ? '-' : (t.type || '-');
|
||||||
|
let nennleistung = t.mw ? t.mw.toString() : '-';
|
||||||
|
|
||||||
return [
|
return [
|
||||||
t.nr,
|
t.nr,
|
||||||
|
|
|
||||||
Loading…
Reference in New Issue